整县屋顶光伏接入公变的台区保护配置分析

Analysis of the Protection Configuration of the DIstribution Area Containing Rooftop Photovoltaic in Whole County

  • 摘要: 文章主要探讨了屋顶光伏电源接入配网的原则及接入配网后,配网故障进行保护分析,在此基础上,还开展了仿真实验。结果发现,接入之后会对外提供一定的故障电流,配网原有保护灵敏度会出现相应的变化,必须按照仿真结果适当对保护定值进行调整。整县屋顶光伏示范,以接入中压(专变)、低压(公变)为主。本文对小容量光伏接入低压后的台区保护配置开展分析。

     

    Abstract: This paper mainly discusses the principle of rooftop photovoltaic power supply access to the distribution network and analyzes the distribution network fault protection after photovoltaic connection, on this basis, the simulation experiment is carried out. The results show that after access, a certain fault current will be provided, after photovoltaic connection,and the original protection sensitivity of the distribution network will change accordingly, so the protection value must be adjusted according to the simulation results. The whole county rooftop photovoltaic demonstration, mainly access to medium voltage (special transformer), low voltage (public transformer). This paper analyzes the protection configuration of the distribution area after the small capacity photovoltaic power is connected to the low voltage.

     

/

返回文章
返回